Force Plates Will Not Power On

If your Hawkin force plates are fully charged but will not power on, the most common cause is an incompatible charging adapter supplying too much power to the battery. To protect the internal electronics, the battery management system may place the plate into a protective "Safe Mode" state.

Fortunately, this issue can often be resolved with a simple battery reset and charger replacement.

Follow the troubleshooting steps below in order before contacting support.


Step 1: Confirm the Charging Light Behavior

First, verify the LED behavior while the plates are plugged in:

  • Flashing Orange Light = Battery is charging
  • Solid Orange Light = Battery is fully charged

If the plates show a solid orange light but will not power on, continue to Step 2.


Step 2: Disconnect the Charger and Inspect It

Unplug the charger from the force plate.

Take a photo of:

  • The wall adapter (charging block)
  • The charging cable
  • The charger connected to the plate (if possible)

Many recent power-related support cases have been caused by third-party charging adapters that deliver more power than the plate is designed to accept.

If your charger has caused the battery to enter Safe Mode, additional charging will not resolve the issue.


Step 3: Perform a Battery Reset

With the charger disconnected:

  1. Press and hold the power button for at least 30 seconds
  2. Release the button
  3. Press the power button again normally

This process attempts to reset the battery management system and wake the plate from Safe Mode.

If the plate powers on, proceed to Step 4.

If it still does not power on, skip to Step 7.


Step 4: Replace the Charger

If the battery reset resolves the issue, we strongly recommend replacing the charger before continuing to use the system.

You can order a replacement charger here:

Replacement Charger

Using an incompatible charger may cause the issue to occur again.


Step 5: For Gen 5 Plates Using a Magnetic Charger

If you are using a Gen 5 magnetic charger:

  1. Disconnect the magnetic charging cable
  2. Reconnect it securely
  3. If necessary, rotate or flip the magnetic connector and try again

Occasionally the magnetic connection may not seat properly, preventing the battery from charging.


Step 6: Verify Charging Hardware

If the plates still will not power on:

  • Try a different wall outlet
  • Try a different charging cable
  • Try a different charging block/USB power adapter

For Gen 5 systems, you may also attempt charging with the tablet's USB-C charger if available.

If the charging LED begins flashing orange with an alternate charger, discontinue use of the original charger and order a replacement.


Step 7: Verify the Correct Charging Port (Gen 3 Plates)

For Gen 3 force plates, confirm you are charging through the correct port.

Ensure the charging cable is connected to the:

✅ Charge Port

Not the:

❌ Comms Port

Charging through the incorrect port will prevent the battery from charging.


Step 8: Contact Support

If the force plates still will not power on after completing all troubleshooting steps above, please contact:

techsupport@hawkindynamics.com

Include:

  • A photo of the charger
  • A description of the LED behavior
  • The force plate serial number(s)
  • Any troubleshooting steps already attempted

Step 9: Prepare for a Support Call

For persistent battery issues, Hawkin Support may schedule a brief call to perform additional battery maintenance.

Before the call:

  1. Locate a T10 screwdriver
  2. Remove the rear cover of the primary (right) force plate
  3. Leave the plate open and ready for troubleshooting

A Hawkin support representative will guide you through the remaining steps during the call. In most cases, this process only takes a few minutes and successfully restores power functionality and accurate battery reporting.